BioRad Variant Hemoglobin Analyzer
The VARIANT Short
Program provides detection and presumptive identification of hemoglobins
S, F, A, C, D and E in newborn patients. Rapid analysis and unattended
operation maximize productivity and efficiency. The program provides
objective patient reports, unlike traditional methods.
Request Asset 04239, or 04238

Sartorius
Sartocheck 3 Filter Integrity Tester
The Sartocheck 3 is a fully automatic, microprocessor controlled filter
integrity tester. It is programmable, storing 60 programs internally and
up to 240 programs with a memory card. The Sartocheck 3 can carry out 6
common tests. The result of the test and the test data being printed out
in a format to meet cGMP requirements.
Internal reference tank allows net volume determinations, up to 6 litres,
to be carried out on every test to retain accuracy. External tank is
available for larger volumes
Request Asset 09854
 Overstocked
Microscopes
GMI has recently acquired many microscopes.
Leica, Fisher Scientific, American Optical, Nikon, Wild Heerbrugg
to name a few!!
Click here to see additional information

Perkin
Elmer 650-10M Spectrofluorometer The
Perkin-Elmer 650-10M Fluorescence Spectrophotometer is one of the most
sensitive instruments for measuring organic compounds that contain a
fluorescing functional group. This instrument is used in biochemistry
and instrumental analysis.
100/240v 50/60hz .03-.05A Request Asset
09450

MJ
Research PTC150 Minicycler Thermal Cycler With
25-well block which holds 25 x 0.2mL tubes or one V-bottom Microplate,
2cm-thick pad for 25-well block, easy-to-read programming interface,
small footprint 9x11in., light-weight 7lbs., Hot Bonnet heated lid,
temperature range from -9ºC to 105ºC, stores up to 80 programs of up to
100 steps, total steps of 400 for all programs. Request Asset
09709

Perkin
Elmer 9600 Gene Amp PCR Thermal Cycler The system 9600 combines
integrated instrument design, thin-walled 0.2 mL reaction tubes and a
96-well format to offer greater speed, oil-free operation, lower
reaction volumes, unsurpassed cycle time reproducibility and
high-performance PCR protocols. Request Asset
09341

Thermo
Forma Stericycle 370 Co2 Incubator Can be
sold single or dual (stacked) each is 6.5 cubic foot direct heat CO2
incubator with T/C CO2 sensor, HEPA filter and heat sterilization cycle
Request Asset
09531

Haemonetics
M215 Apheresis System
The machine
collects whole blood from a healthy donor into a sterile, single use
disposable kit. The blood flows into a plastic bowl (part of the disposable
kit) and through centrifugal force is separated into its component parts.
The platelets are harvested into a collection bag, and the remaining blood
components - plasma and red cells - are returned to the donor. The
advantages of this system are two-fold: (1) the collection of up to two
therapeutic doses from a single donor, and (2) platelet transfusion safety
for the recipients, thanks to the reduction or elimination of pooling Request Asset 09364

MLA
800 Automated Coagulation System
Reagent
storage area onboard
Numeric temperature display
Reagent pumping system
Reagent heat exchanger-precise temps
Photo optical system c/ 4 sensors analyze two cuvettes simultaneously
Twin well cuvettes
Cuvette sensing device
Automatic cuvette disposal system Request
Asset 08912

Labline
3527 Tabletop Incubator Shaker
The Lab-Line 3527 shaking
incubator allows for higher shaking speeds and higher aeration rates
compared to water bath shakers. Triple eccentric drive provides circular
orbit of 19 mm (3/4") to give smooth, swirling motion to samples in all
vessels. Solid-state speed control varies agitation speed from 40 to 400
rpm. This incubator is equipped with a 18x18" shaking platform and will
accommodate Erlenmeyer flasks up to 2L. Speed: 40 to 400 rpm. Orbit: 19mm
(3/4"). This unit is equipped with coils for water cooling. Temp. Range:
From slightly above cooling water temp. up to 65C. Request Asset 09173

Thermo
Shandon Pathcentre Tissue Processor
The
practical design of the Shandon Pathcentre provides a 306-cassette capacity
basket plus the ability to add up to three extra processing modules for high
throughput laboratories. The Shandon Pathcentre’s "Closed Loop System"
ensures that fumes stay within the system and do not escape into your lab,
resulting in fewer changes of charcoal filters. A gentle counter-stir
agitation and tidal flow system combine to promote maximum fluid penetration
through baskets and cassettes for excellent processing quality and
consistency. A circular reaction chamber optimizes temperature uniformity,
and enhances continuous agitation.
Request Asset 09170
Load
multiple 20-slide baskets on the machine.
Intuitive software makes it possible for the Shandon Varistain Gemini to
perform separate protocols simultaneously with multiple baskets in process.
Units available with or without five independently heated positions for
drying slides. Units have 6 water stations, 26 reagent stations, and a total
of 4 configurable doors for loading and unloading.
Battery back-up provides 40 minutes of power.
Request Asset 09169
4-bay high-throughput thermal cycling. Up to 8
individual sample blocks, which can be controlled independently or as a
groupUp to 1536 samples can be processed simultaneously. Internal power supply-no separate "boxes" to accommodate. High-density color display and on-board mousepad, with
point-and-click navigation of software.
Real-time monitoring of cycling temperatureExtraordinary temperature
uniformity of ±0.4°C within 30 seconds of arrival at 90°C, well-to-well
average (±0.5°C for dual block Alphas).
Request Asset
09100

The
J-6B Among the largest capacity of centrifuges, this floor model permits
side by side operation by venting to the rear. And it operates over the
temperature range of -20 o to 40 o C with a low heat output of just 6500
Btu/hr. Request Asset 09003

IBM
2991 Blood Cell Processor
The IBM
2991 Blood Cell Processor, normally used to wash or deglycerolize red blood
cells, has been modified to permit serial plasmapheresis using a small
roller pump, an adapter line and the disposable processing set usually used
for cell washing. Blood is withdrawn from the donor, pumped into the plastic
centrifuge bag and the plasma removed after centrifugation. Donor
erythrocytes are pumped from the processing bag to a reservoir bag from
which they are returned to the donor by gravity. Multi-unit plasmapheresis
to harvest plasma for transfusion or to remove plasma as a therapeutic
measure is possible using the modified system.
Request Asset 09060

4
ft. Fume Hood and 6 ft. Fume Hood
Labconco chemical Fume Hoods: Models 4880400 (4ft) and
9750600 (6 ft), both with base cabinets, and chemical resistant counter
tops.
Request Asset 09119

Perkin
Elmer 480 DNA Thermal Cycler
The DNA Thermal Cycler 480 is designed for small sample volumes, reducing
reagent cost. The system has a 48-well block that uses 0.5-ml tubes and a
two-temperature protocol for lower reagent requirements. The DNA Thermal
Cycler 480 is designed for small sample volumes, reducing reagent cost. The
system has a 48-well block that uses 0.2-ml tubes and a two-temperature
protocol for lower reagent requirements. Request Asset 08952

Beckman
DU64 Spectrophotometer
This DU64 UV-visible scanning spectrophotometer is in perfect working order,
excellent proven optics, bandpass of appx. 1.8 nm.
Request Asset 09052

Hewlett
Packard 3396C Series III Integrator
Features A/D conversion of continuously integrating dual slope with 100%
area conversion, input range is -10 mV to +1000mV. Read/write memory is
65,536K of static RAM, read-only memory is 192K total, electronic disk
storage is 35,584 bytes with a maximum peak storage capacity of 1240 peaks.
A full range of methods are available, including area%, height%,
normalization and both external and internal standards. Includes up to 63
levels for multi-level calibrations with a choice of curve fits Request Asset 08939

MJ
Research PTC-100 Thermal Cycler 60 Well
The MJ
Research PTC-100 is a 96, 60 or Dual 48 well thermocycler that also uses a
heated lid for oil-free operation plus the following features: Improved Hot
Bonnetª heated lid incorporates a thumbwheel to adjust height and pressure.
This feature assures tight sealing of reaction vessels --even microplates--
during oil-free thermal cycling. Precise Peltier-effect heat pumps
--robustly designed for repeated cycling-- deliver the full temperature
range of 0-100C electronically, in a compact instrument with a footprint
that measures 24cm x 28cm x 27cm high. Speedy ramping rates of; up to
1.4¡/sec in models that hold 0.2ml tubes or V-well plates; Unparalleled
temperature homogeneity: ±0.4C within 30 seconds of arrival @ 60C for all
standard models. Request Asset 09002

Shandon
AS620 Cryostat
For
superb sectioning from a variety of tissues, depend on AS620 cryotome. The
microtome is situated outside the cryochamber, which makes it far easier to
clean and disinfect the working area. Microtome maintenance is held to a
minimum. Request Asset 08822

Thermo
Savant Modulyo D Freeze Dryer
Digital display of vacuum and temperature. Robust
design and high quality smooth wall stainless steel with bottom drain. RS232
port for collecting critical data. CFC-free refrigeration. Request Asset 08669

If you would like to comment, or have suggestions, please
email us at paula@gmi-inc.com.
We always welcome feedback from our customers
and read all responses.
GMI ....instrumental to science! GMI Ships Worldwide |