Wait on & Wait off timer
Accurate temperature control with 3-point calibration
Settings for temperature deviation
Manipulation via PC (option)
Real-time monitoring via mobile devices (LC GreenBox: option)
Removes fume from the inside of the chamber
Safe surface even at maximum temperature
Logs the recent 12 events
Increased space utilization by double stacking (stacking set : option)
Model | Solid Door (without window) | ON4-03S | ON4-05S | ON4-10S | ON4-15S |
---|---|---|---|---|---|
Window door | ON4-03SW | ON4-05SW | ON4-10SW | ON4-15SW | |
Chamber volume (L / cu ft) | 26 / 0.92 | 58 / 2.05 | 110 / 3.88 | 147 / 5.19 | |
Temperature | Range (℃ / ℉) | Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Fluctuation at 100℃ (±℃ / ℉) | 0.4 / 0.72 | 0.5 / 0.90 | 0.5 / 0.90 | 0.5 / 0.90 | |
Variation at 100℃ (±℃ / ℉) | 2.8 / 5.04 | 2.6 / 4.68 | 3.6 / 6.48 | 3.5 / 6.30 | |
Heating time to 100℃ (min.) 1) | 25 | 39 | 22 | 21 | |
Recovery time at 100℃ (min.) | 17 | 19 | 10 | 9 | |
Control panel | 3.5 inch TFT Color LCD | ||||
Communication interface | USB-B, RS-232 (option) | ||||
Function | Recently event record | 12 ea | |||
Dimension (W×D×H) |
Interior (W x D x H, mm / inch) | 273 x 270 x 350 / 10.75 x 10.63 x 13.78 |
340 x 390 x 422 / 13.4 x 15.35 x 16.61 |
441 x 420 x 597 / 17.36 x 16.54 x 23.5 |
500 x 446 x 659 / 19.69 x 17.56 x 25.95 |
Exterior (W x D x H, mm / inch) | 478 x 527 x 604 / 18.8 x 20.75 x 23.78 |
558 x 648 x 684 / 21.97 x 25.5 x 26.93 |
663 x 677 x 859 / 26.1 x 26.65 x 33.82 |
728 x 704 x 914 / 28.66 x 27.7 x 36.0 |
|
Net weight (Kg / lbs) | 33 / 72.8 | 53 / 116.8 | 63 / 138.9 | 73 / 160.9 | |
Shelves | Quantity of shelves (standard/max.) | 2 / 4 | 2 / 5 | 2 / 8 | 2 / 9 |
Max. Load per shelf (Kg / lbs) | 20 / 44.09 | 20 / 44.09 | 20 / 44.09 | 20 / 44.09 | |
Number of air change per hour at 100℃ | 16 | ||||
Electrical requirements (230V, 50 / 60Hz, A) | 3.2 | 3.5 | 5.7 | 7.4 | |
Cat. No. |
Solid Door (without window) | AAH15045K | AAH15065K | AAH15075K | AAH15085K |
Window door | AAH15145K | AAH15165K | AAH15175K | AAH15185K | |
Electrical requirements (120V, 60Hz, A) | 6 | 6.7 | 10.9 | 14.2 | |
Cat. No. |
Solid Door (without window) | AAH15046U | AAH15066U | AAH15076U | AAH15086U |
Window door | AAH15146U | AAH15166U | AAH15176U | AAH15186U |
¹⁾ Heating time is defined as the time taken to reach 98% of the set temperature.
※ Technical data according to DIN 12880
To view available parts for this instrument and instruments like it, click here.
Our parts and accessories inventory is constantly changing. Don't see what you're looking for? Give us a call, we'll be happy to help.
Service Agreements |
Silver |
Gold |
First Class Ship & Fix |
Economy Ship & Fix |
Preventative Maintenance Visit | 1 Preventative Maintenance Visit per Year | 1 Preventative Maintenance Visit per Year | ||
Parts Covered | ||||
Labor Covered | ||||
Unlimited Remote Tech Support | ||||
Depot Repair | ||||
Depot Preventative Maintenance |