Graphs for real-time process monitoring
Depth of less than 750 mm allows stable positioning on lab table
Uniform temperature control with multi-path airflow
Timely responses via BMS-connected monitoring (BMS port: option)
Real-time monitoring via mobile devices (LC GreenBox: option)
Data storage using USB ports
Store recent 36 events
Accurate temperature control with 3-point calibration
Ramp Control™ per experiment condition
Model | Solid Door (without window) | ON4-03V | ON4-05V | ON4-10V | ON4-15V |
---|---|---|---|---|---|
Window door | ON4-03VW | ON4-05VW | ON4-10VW | ON4-15VW | |
Chamber volume (L / cu ft) | 26 / 0.92 | 58 / 2.05 | 110 / 3.88 | 147 / 5.19 | |
Temperature | Range (℃ / ℉) | Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Amb. +15 to 250 / Amb. +59 to 482 |
Fluctuation at 100℃ (±℃ / ℉) | 0.4 / 0.72 | 0.5 / 0.90 | 0.5 / 0.90 | 0.5 / 0.90 | |
Variation at 100℃ (±℃ / ℉) | 2.8 / 5.04 | 2.6 / 4.68 | 3.6 / 6.48 | 3.5 / 6.30 | |
Heating time to 100℃ (min.) 1) | 25 | 39 | 22 | 21 | |
Recovery time at 100℃ (min.) | 17 | 19 | 10 | 9 | |
Control panel | 5 inch TFT Color LCD | ||||
Communication interface | USB-B, RS-232 | ||||
Function | Recently event record | 36 ea | |||
Recommended temperature | Suggest three frequently used temperature | ||||
Graph | Available viewing stored and real-time graphs | ||||
Data storage | Save your experiment data (in CSV format) | ||||
Temp. ramping rate (℃/min. | ℉/min) | 0 to 2.2 | 0 to 3.96 | 0 to 2 | 0 to 3.6 | 0 to 4.4 | 0 to 7.92 | 0 to 2.6 | 0 to 4.68 | |
Dimension (W×D×H) |
Interior (W x D x H, mm / inch) | 273 x 270 x 350 / 10.75 x 10.63 x 13.78 |
340 x 390 x 422 / 13.4 x 15.35 x 16.61 |
441 x 420 x 597 / 17.36 x 16.54 x 23.5 |
500 x 446 x 659 / 19.69 x 17.56 x 25.95 |
Exterior (W x D x H, mm / inch) | 478 x 527 x 604 / 18.8 x 20.75 x 23.78 |
558 x 648 x 684 / 21.97 x 25.5 x 26.93 |
663 x 677 x 859 / 26.1 x 26.65 x 33.82 |
728 x 704 x 914 / 28.66 x 27.7 x 36.0 |
|
Net weight (Kg / lbs) | 33 / 72.8 | 53 / 116.8 | 63 / 138.9 | 73 / 160.9 | |
Shelves | Quantity of shelves (standard/max.) | 2 / 4 | 2 / 5 | 2 / 8 | 2 /9 |
Max. Load per shelf (Kg / lbs) | 20 / 44.09 | 20 / 44.09 | 20 / 44.09 | 20 / 44.09 | |
Number of air change per hour at 100℃ | 16 | ||||
Electrical requirements (230V, 50 / 60Hz, A) | 3.2 | 3.5 | 5.7 | 7.4 | |
Cat. No. |
Solid Door (without window) | AAH111105K | AAH111115K | AAH111125K | AAH111135K |
Window door | AAH112105K | AAH112115K | AAH112125K | AAH112135K | |
Electrical requirements (120V, 60Hz, A) | 6 | 6.7 | 10.9 | 14.2 | |
Cat. No. |
Solid Door (without window) | AAH111106U | AAH111116U | AAH111126U | AAH111136U |
Window door | AAH112106U | AAH112116U | AAH112126U | AAH112136U |
Heating time is defined as the time taken to reach 98% of the set temperature.
※ Technical data according to DIN 12880
¹⁾ Heating time is defined as the time taken to reach 98% of the set temperature.
※ Technical data according to DIN 12880
To view available parts for this instrument and instruments like it, click here.
Our parts and accessories inventory is constantly changing. Don't see what you're looking for? Give us a call, we'll be happy to help.
Service Agreements |
Silver |
Gold |
First Class Ship & Fix |
Economy Ship & Fix |
Preventative Maintenance Visit | 1 Preventative Maintenance Visit per Year | 1 Preventative Maintenance Visit per Year | ||
Parts Covered | ||||
Labor Covered | ||||
Unlimited Remote Tech Support | ||||
Depot Repair | ||||
Depot Preventative Maintenance |