Amerex AT-HG-113*

Amerex AT-HG-113*

Manufacturer:
Amerex
SKU#:
8021-10-0017

HIRAYAMA HG-SERIES AUTOCLAVES WITH AN INNOVATIVE FEATURE...JUST PRESS A BUTTON TO AUTOMATICALLY OPEN THE LID, OR CLOSE AND LOCK IT.

For more information or to place an offline order call 1-800-745-2710

OR

We Accept Trade-ins!

Don’t forget to tell us about any unused

instruments taking up space in your lab.

Description

These six of eight models of the HG series do not offer a drying cycle. (Series models with drying are HGD-113 and HGD-113). The chamber diameter of the 50L HG-50 and 80L is 36.4 cm (14.3”) chamber whereas that of the 113L HG-113, HGS-113, HG-133 and HGS-133 is 50 cm (19.7’). HGS-113 and HGS-133 incorporate a steam generator. Features include the following:

  • Automatic Lid Opening Button replaces a foot pedal.
  • Automatic Lid Closing Button closes lid conveniently and safely.
  • Safety Interlock senses pressure and temperature and prevents lid from opening during a cycle, when the chamber is pressurized, and when the high temperature can cause boil over.
  • Programmable Auto-Start for running a cycle from 1 to 99 hours later.
  • Large (15 liters) / Efficient Steam Condenser ensures no steam exhausts into the lab.
  • Over-Flow Lamp indicates that the drain bottle is full and ready to be emptied.
  • Built-in Cooling Fan for faster post-sterilization cooling and shorter completion time.
  • Selectable Rate of steam venting after sterilization.
  • Programmable Time for air removal before sterilization.
  • Twelve Programs Cycles can be stored.
  • Large Control and Display Panel improves functionality and shows the progress of the sterilization cycle.
Specification

HG-50 and HG-80 Specifications

MODEL
HG-50
HG-80
Overall (W x D x H)
19.7" x 27.2" x 35.0"
(45.5 cm x 69.1 cm x 89.0 cm)
19.7" x 27.2" x 40.6"
(45.5 cm x 69.1 cm x 103.0 cm)
Chamber
(Diameter x Height)
50 liters
14.3" x 19.0" (36.4 cm x 48.2 cm)
76 liters
14.3" x 28.7" (36.4 cm x 73.0 cm)
Temperature Range
105°C to 135°C
Sterilization Timer
1 to 300 minutes
Agar Warming Range
After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start
Program autoclave to start 1 to 99 hours later
Cooling Fan
Switch to turn fan on or off
Air Removal Timer
Programmable, 3 to 9 minutes after temperature has reached 97°C
Steam Venting
Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock
Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles
1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution
Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol
Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.
Safety Features
Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser
15-liter water tank
Drain Water Bottle
2 liters
Power Requirements
120V or 220V, 50/60 Hz, single phase
220V, 50/60 Hz, single phase
Power Consumption
2.0kW, optional 3.0kW for 220V only
3.9 kW
Shipping Weight
180 lb (82 kg)
255 lb (116 kg)
Services
GMI Certified Service means:
  • Healthy operation of your instrument
  • Helping to ensure the quality of your results
  • Lowering cost of ownership through multilple service agreement options
  • Prolonging instrument serviceable life
  • Safe Operation of your equipment
  • Minimizing downtime increases productivity and minimizes revenue loss
  • Instrument Evaluation Services
  • Contract Refurbishing
  • Relocation Services
  • Equipment Finder Service
  • Training Courses
  • Depot Repair
  • Instrument Decommisioning & Disposal Services
Service Agreements


Bronze
Prevention
Plus
Silver
Assurance
Plus
Gold
Safety
Plus
Platinum
Premium
Plus
PM
Preventative Maintenance Visit
('tune up', including cleaning, lubrication, and adjustments)
1PM
or
1 Service Visit
Service Visit 1PM
or
1 Service Visit
1 2
Travel
Parts and Labor    

1 YEAR
Discounted Parts
Discounted Labor (As needed)
Parts

Lab Equipment Replacement Parts & Accessories

Click button to view parts which are available for this instruments and instruments like it in our brand new online parts shop.

We also carry instruments parts for the following other instruments categories.

WHY BUY FROM GMI?

Your trusted source for new, factory clearance & certified pre-owned lab instruments since 1995.

  • We routinely save discerning laboratories 30-80% with our recertified pre-owned and factory clearance instrument offerings.

  • Quality? ISO 9001:2008 certified means we remove 100% of the risk in buying ‘used’ laboratory equipment.

  • Warranties from 90 days to a year as well as multi-year service agreements are available.

GMI is an ISO 9001:2008 certified company - proof that your instruments pass through a rigorous re-certification process to ensure that it arrives at your laboratory defect-free and in full working order.
We are neither an auction company nor an instrumentation broker. GMI employs our own factory-trained engineers to ensure full control of this process.
Unlike small-time businesses and brokers, GMI goes beyond offering money-back promises. We offer real product warranties.
Apart from our meticulous inspection processes, GMI’s available warranties and multi-year service agreements guarantee customer satisfaction - no need to go through frustrating and time-consuming product returns!
Additionally, all items are thoroughly cleaned and professionally packaged/crated with care to insure they arrive in your lab ready for use.