Weight | 1600 oz |
---|---|
Dimensions | 40 × 48 × 48 in |
Manufacturer | |
Instrument Type |
At Agilent, building the world’s most trusted GC/MS solutions is an ongoing challenge and a process of continual improvement. With each new generation of instruments, we never lose sight of our goal—to help your lab get better results with higher confidence, and process more samples in the shortest possible time.
The gold standard in quadrupole design and performance
The quadrupole used in the Agilent 5975C Series GC/MSD incorporates a combination of patented, proprietary Agilent technologies to deliver superior performance and significantly enhanced reliability.
The true hyperbolic quartz structure offers extremely low thermal expansion, and exhibits excellent dimensional stability. The unique design results in lower field errors versus round rod quadrupoles, as well as excellent resolution and mass axis stability, regardless of laboratory temperature fluctuations.
The submicron-layered gold hyperbolic electrode surfaces give maximum transmission while maintaining resolution across the full mass range, up to 1050 u. Bakeout to 200ºC enables more robust determinations, as well as outstanding high mass stability and minimal maintenance. An available high mass checkout kit provides added confidence that high mass is accurately reported.
Solid inert ion source up to 350? C boosts your system performance
Agilent’s proprietary inert source is now programmable up to 350?C to provide enhanced response for active compounds and late-eluters—including pesticides. It delivers exceptional electron impact ionization, and lets you run sample after sample with complete confidence. The source is constructed of a solid inert material, so there is no inert coating that can wear away over time— and which can ultimately compromise your data. The inert ion source eliminates surface activity reactions, for more reliable library matches. It also requires less frequent cleaning, improving your lab’s productivity.
The inert ion source eliminates surface activity reactions, for more reliable library matches. It also requires less frequent cleaning, improving your lab’s productivity.
Trace Ion Detection delivers a real performance improvement for complex matrices
Revolutionary Trace Ion Detection technology lets you lower your Method Detection Limit (MDL), as well as your limit of quantitation (LOQ). It reduces false negatives and further enhances the performance of the inert ion source at trace levels. The technology also ensures more reproducible baselines, dramatically reducing the number of manual interventions during peak integration. Trace Ion Detection technology gives you a better spectral fidelity, increasing your confidence level in the results when doing library matching.
High sensitivity AutoTune makes it easy to optimize system performance
Take the trial and error out of optimizing operating conditions by automating the process. The 5975C system’s AutoTune feature saves time, boosts performance and improves instrument-toinstrument consistency.
Fast electronics enhance performance and enable synchronous SIM/Scan
Fast electronics used in the 5975C Series GC/MSD maximizes signal transmission for fast GC/MS in full scan and Selected Ion Monitoring (SIM) modes. It also enables synchronous SIM/Scan functionality—without compromising analytical performance.
High-Performance Selected Ion Monitoring (SIM) and Full Scan
Agilent’s synchronous SIM/Scan functionality lets you capture SIM data and full scan data in the same acquisition. Because of the ease of setup and availability of spectral libraries, many labs use full scan for most of their data collection. SIM mode, on the other hand, offers a significant improvement in sensitivity over full scan data; however, SIM data cannot be searched against commercially available spectral libraries for match confirmation.
Now, with the 5975C system’s synchronous SIM/Scan operation, you can get both—in a single run! Even better, you don’t have to be a GC/MS expert to do it. Agilent’s AutoSIM software capability automatically converts full scan data into SIM or SIM/Scan acquisition parameters for use in synchronous SIM/Scan methods. SIM dwell times can be set in 1 msec increments from over 100 msec to as low as 1 msec dwell time.
CI as easy as EI
Chemical Ionization (CI) has long been considered an advanced GC/MS technique because of complex setups, reagent gas adjustment and ion source tuning. Now the Agilent 5975C inert GC/MSD makes CI as routine and easy as EI—without sacrificing the spectral information of EI. The dual inlet port configuration allows you to operate your CI system at optimum performance levels without having to constantly reconfigure. Methane is used to optimize the ion source and perform the mass calibration; a separate inlet port is provided for a second reagent gas, including ammonia. An intuitive software user interface and a CI flow control module work together to automatically adjust the CI reagent gas flow for optimum CI performance.
Adding an exciting new chapter to a 40-year history of GC leadership, Agilent’s new 7890A flagship GC gives you everything you need to take your lab to the next level of GC/MS performance, including advanced chromatographic capabilities, powerful new productivity features and real-time self-monitoring instrument intelligence. Plus, of course, legendary Agilent reliability.
Agilent Performance and Reliability
5th-generation electronic pneumatics control (EPC) and digital electronics set a new benchmark for retention time locking (RTL) precision and retention time repeatability, and help make the 7890A Agilent’s most dependable GC ever.
Expanded Chromatographic Capabilities
Highly flexible EPC design enables even more sophisticated hydrocarbon analyses. An optional 3rd detector (TCD) can speed up complex gas analyses, and allows more types of analyses to be run on a single GC.
Higher Productivity
Faster oven cool-down, robust backflush capability, advanced automation features and faster GC/MS oven ramps let you get more done in less time, at the lowest possible cost per sample— all easily incorporated into your existing methods.
Easier Operation
Practical, time-saving design features speed up and simplify routine maintenance.
You can increase your productivity and take advantage of the new capabilities of the 7890A system with no disruption to your lab’s smooth operation. Right out of the box, operators will be right at home with the familiar controls and user interface—and because the 7890A system is built upon proven 6890 GC inlets, detectors and GC oven, you can transfer methods to your new 7890A GC with complete confidence.
Agilent’s innovative Capillary Flow modules enable reliable, leakfree in-oven connections. Available in a number of useful configurations, these inert, low-mass, low-dead-volume devices not only make it easy to make secure connections, they give you the ability to precisely divert your gas flow, where and when you want. This opens the door to highly useful techniques, such as flow splitting, backflushing and Deans Switching, that can improve your analytical results, as well as saving time and resources.
Convenient new Turn-Top design is built into each split/splitless (SSL) inlet, allowing you to change liners and columns more quickly and easily than ever before—without special tools or training. The Agilent 6850 Series II GC—small, rugged, easy to useIs your lab doing simple, routine applications or at-line analysis? The Agilent 6850 GC, combined with the 5975C VL GC/MSD, is the perfect choice if you need just a single inlet and detector. The small-footprint system offers a surprising number of advanced features—as well as legendary Agilent reliability.
The Agilent MSD Productivity ChemStation makes it easy even for non-expert operators to take advantage of all the advanced capabilities of the Agilent 5975C inert GC/MSD system. You’ll find everything designed to help you make the most of every run, and every workday. The MSD ChemStation software includes four industryfocused packages: Enhanced Mode, EnviroQuant, DrugQuant and Aromatics in Gasoline.
• Control of two GC/MS systems from a single MSD ChemStation via built-in LAN communication saves time, resources and bench space.
• Automatic tuning ensures more accurate results every time for EI, PCI and NCI modes.
• Retention Time Locking (RTL) gives you repeatable retention times across systems regardless of operator, detector type and column maintenance. In combination with Agilent or user-created databases, it will let you quickly screen unknown peaks with added confidence.
• Synchronous SIM/Scan and AutoSIM automatically and easily convert any full scan method to a high sensitivity SIM or SIM/Scan method—enabling you to acquire both SIM and Scan data in a single run.
• eMethods functionality allows you to efficiently share and distribute methods across multiple laboratories or to save development time by downloading application methods from the Agilent Website.
• SemiQuant estimates the concentration of uncalibrated compounds that may be of potential importance.
• Data reprocessing lets you reprocess a previously run sequence while new data are being collected.
• Enhanced Data analysis and Easy EIC tools expand your system’s qualitative analysis capabilities.
• Simple, standard reports or easily customizable reports let you best meet your lab’s needs. A variety of reports may also be easily exported to XLS, HTML or XML formats.
• Advanced macro programming provides additional capability for customization.
• Integrated control of PAL autosamplers enables automated, largevolume sample injection. (Available option)
• Deconvolution Reporting Software (DRS), combined with application-specific Retention Time Locked Libraries, reduces hours of manual data review to only minutes of automated processing. (Available option)
• Integration with Agilent OL Enterprise Content Manager (ECM) makes it easy to store, retrieve and organize GC/MS methods, data and reports.
Agilent’s SemiQuant capability works together with Retention Time Locking (RTL) databases to increase confidence in your compound identification and speed up the quantification process.
When an unknown peak appears, a library search provides only a possible match with the sample spectrum. Using the appropriate RTL database, you can increase certainty by matching the retention time of your compound with a fixed retention time in addition to spectral data. Should you wish to quantify the compound, SemiQuant helps by estimating the concentration, so that you can inject the appropriate level of the standard.
With Agilent eMethods, recreating and replicating a new GC/MS method is now a quick and fully automated process. You can bring a new GC/MS online in the shortest possible time, and maximize lab productivity by standardizing on methods—whether your instruments are across the hall, or across the world.
Agilent’s simple, easy-to-use Deconvolution Reporting Software (DRS) is an optional software feature that saves hours of analysis and review. The best deconvolution software in the industry, the software quickly finds compounds that traditional data analysis packages miss. In fact, it reduces data review time from hours of tedious work to minutes of unattended computer analysis.
The DRS software automates the following operations:
• Quantitation by target compound analysis software
• Spectral Deconvolution, or “cleaning” of full scan spectra
• Library searching of cleaned spectra
The revolutionary solution combines three different software packages:
• Agilent’s GC/MSD ChemStation
• The National Institute of Standards and Technology (NIST) Mass Spectral Search Program with the NIST MS Library
• NIST’s Automated Mass Spectral Deconvolution and Identification Software (AMDIS)
Three new database libraries:
• Hazardous Chemical Compounds RTL Database for rapid and accurate identification of chemical agents
• Pesticide and Endocrine Disruptor RTL Database for rapid and accurate quantitation of these agents in large numbers of samples
• Indoor Air Toxics RTL Library for identification and quantitation of toxics in the workplace
Add an Agilent 7683 Series Automatic Liquid Sampler. Offering the fastest injection times of any GC autosampler, greater solvent capacity, multiple sampling options, dual simultaneous injection, certified autosampler vials—and more—the 7683 ALS is ready to go to work.
Choose the versatile CombiPAL sample injector for liquid injection, headspace and solid-phase microextraction (SPME). The economical GC PAL platform can be configured for liquid injection only, but offers many of the other capabilities of the CombiPAL including large volume injection (LVI), multiple vial and syringe sizes, and extended sample vial capacity.
Automatically introduce volatile compounds from virtually any sample matrix directly into a GC or GC/MS. An inert sample pathway from vial through column to source provides superior chemical performance without analyte degradation or loss.
Agilent is the first mass spectrometer manufacturer to offer this unique pump, which requires virtually no routine maintenance. There’s no oil, and no danger of oil contamination or leaking.
Designed for supportability and maintenance
Agilent GC/MSD systems have always been designed for easy serviceability and maintenance—and the Agilent 5975C Series GC/MSD takes this design philosophy to a whole new level.
• Modular analyzer assembly offers complete access to the filament ion source, mass analyzer and electron multiplier for faster routine maintenance—in fact, the entire analyzer assembly can be removed in less than two minutes, without tools! A modular, self-contained electronics module minimizes problems with cables and wiring harnesses.
• Front glass window provides simple source identification, as well as a complete view of critical connections—so you can see for sure the column is connected properly.
• High-reliability vacuum system assures maximum long-term performance; available oil-free pumping system virtually eliminates pump maintenance and reduces noise, and can be used with corrosive gases such as ammonia.
• Off-axis high-energy dynode (HED) detector delivers long life and superior sensitivity. New Electron Multiplier Saver feature further extends system service duty cycle.
• Optional ion gauge helps to troubleshoot and isolate leaks as quickly as possible.
Tired of waiting around for a mass spec to vent before you can change a column out or perform routine inlet maintenance? Using a “QuickSwap” Capillary Flow device, you can safely disconnect the column without venting, and without losing vacuum—in about 30 seconds!
The QuickSwap device can also be used for column backflushing, reducing MSD contamination by high-boiling sample components, shortening analysis time and increasing the lifetime of your ion source.
To help you achieve better results faster, Agilent is continuously improving the cleanliness, convenience and reliability of columns and supplies for Agilent GC/MSD systems. From market-leading J&W columns—with rigorous quality control and QC testing that ensure reproducibility, efficiency and inertness—to GC flow path supplies designed, manufactured and packaged to maintain the integrity of your sample, Agilent columns, supplies and accessories will improve your lab’s performance, productivity and confidence.
Choose Agilent J&W columns and supplies for a leak-free, inert flow path to ensure lowest bleed and best signal-to-noise performance in Agilent GC/MSD systems. From among the full suite of Agilent low-bleed J&W columns, the inert HP-5MSi column was selected to ship with the new 5975C. Specially tested to ensure maximum area response performance of strong acid and base compounds, this column is also compatible with Agilent Pesticide Libraries for MS.
Tight inlet seals are needed to keep MS system performance at its peak. Agilent liners pre-cleaned and conditioned liner O-rings— matched with our new, proprietary, injection-molded gold-plated seal—prevent the tiniest leaks that cause column bleed, and signal deterioration.
Agilent supplies help keep routine maintenance routine. Our capillary column ferrules, O-rings and septa are packaged to not only remain clean and ready for use, but to conveniently dispense one at a time as needed for fast inlet maintenance.
An exclusive non-stick plasma coating on our premium inlet septa and pre-cleaned O-rings makes maintenance quicker and easier— no unscheduled inlet maintenance due to residue on the inlet surface, and shorter bakeout times after preventive maintenance, so you can start running samples sooner.
Agilent J&W columns and supplies ensure your Agilent 5975C system delivers as promised. In fact, our GC and GC/MS instrument specifications are determined using industry-leading Agilent J&W columns and Agilent brand chromatography supplies. Eliminate concerns about lost samples or productivity from unexpected sequence interruptions by using Agilent certified autosampler vials, septa and caps, and Gold Standard syringes. Each comes with a Certificate of Conformance to assure you all specifications are met.
Weight | 1600 oz |
---|---|
Dimensions | 40 × 48 × 48 in |
Manufacturer | |
Instrument Type |
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.