Weight | 1600 oz |
---|---|
Dimensions | 40 × 48 × 48 in |
Model | VO29COOL, VO49COOL |
Low-temperature vacuum drying enables pharmaceutical or food labs to gently dry bacteria and starter cultures in the cooled vacuum oven VOcool.
VO Cool Vacuum Ovens feature Memmert’s signature Peltier Cooling Technology. Memmert is the only manufacturer worldwide offering digital pressure control as a standard for vacuum ovens. This system saves up to 70% of energy costs and efficiently cools samples.
Low-temperature vacuum drying enables pharmaceutical or food labs to gently dry bacteria and starter cultures in the cooled vacuum oven.
Vacuum pump (PMP) sold as an accessory
Low-temperature vacuum drying enables pharmaceutical or food labs to gently dry bacteria and starter cultures in the cooled vacuum oven VOcool.
Cooled Vacuum Ovens save both time and energy. The digital pressure control system saves up to 70% of energy costs compared to uncontrolled vacuum pumps, while still effectively cooling the contents of the oven. Processes are optimized and drying times are reduced thanks to the Cooled Vacuum Oven’s ramp programming system. Memmert utilizes resources carefully in the development of products like the Cooled Vacuum Oven, so environmental protection can be the norm.
Stainless steel construction inside and out. Memmert appliances feature welded/ rounded edges within the stainless steel chamber for a hygienic and easy-to-clean interior.
Appliance size | 29 | 49 | |
Appliance width D1 [mm] | 550 | 550 | |
Appliance height E1 [mm] | 600 | 680 | |
Appliance depth F1 [mm] | 400 | 480 | |
Depth of door lock [mm] | 38 | ||
Chamber width A1 [mm] | 385 | 385 | |
Chamber width B1 [mm] | 305 | 385 | |
Chamber width C1 [mm] | 250 | 330 | |
Base
|
Width G [mm] | 529 | 529 |
Height H [mm] | 450 | 290 | |
Depth I [mm] | 383 | 463 | |
Chamber volume [litres] | 29 | 49 | |
Weight [kg] | 71 | 90 | |
Power [W] | 820 | 2020 | |
Current consumption [A] 230 V, 50/60 Hz | 3.6 | 8.8 | |
max. number of thermoshelves | 1 | ||
max. load per Thermoshelf [kg] | 20 | ||
max. load per appliance [kg] | 60 | 80 | |
Temperature
|
Adjustment range | 5 °C to 90 °C | |
Adjustment precision | 0.1 K | ||
Operating temperature range | 5°C above room temperature up to 200°C | ||
Pressure
|
Adjustment range | 5 mbar – 1100 mbar | |
Adjustment precision | 1 mbar | ||
Leak rate | ≤ 0.5 x 10-2 mbar 1/sec | ||
Coolant
|
Coolant | G12 | |
Filling quantity | approx. 800 ml | approx. 1000ml |
The more complex twin display allows users to control every aspect of equipment functionality. Even complex processes such as multiple overtemperature protection, visual and acoustic alarm as well as automated alarm messages can be programmed quickly and easily.
Weight | 1600 oz |
---|---|
Dimensions | 40 × 48 × 48 in |
Model | VO29COOL, VO49COOL |