TO-14 Air Monitoring GC

TO-14 Air Monitoring GC

SKU#:
8331-10-0051
  • Dual trap TO-14 air concentrator
  • PID and combination FID/DELCD detectors
  • Vacuum pump with PeakSimple controlled interface 
  • Built-in "whisper quiet" air compressor
  • 6 channel PeakSimple data system
  • 60-meter capillary column on the compact 8610C chassis

For more information or to place an offline order call 1-800-745-2710

OR

We Accept Trade-ins!

Don’t forget to tell us about any unused

instruments taking up space in your lab.

Description

For TO-14 analysis and ambient air analyses of all types, this GC has everything you need in a compact, easy-to-transport package.

The dual trap TO-14 Air Concentrator is similar to our purge & trap, but it has a gas inlet instead of a liquid purge vessel (a liquid purge head can be added if required). The innovative dual trap design results in more efficient trapping and desorption than single trap designs, especially for early eluting peaks such as vinyl chloride. Please see page 72 for more information on the TO-14 Air Concentrator.

The 60-meter capillary column is the newest unbreakable, fused silica-lined, stainless steel technology, which gives good separation of the TO-14 analytes with short run times. The PeakSimple data system controls and sequences the entire analysis, collecting the data from the three detectors, loading and desorbing the traps, then calculating and printing the results.

Since it is small enough to take on-site for real-time measurements, you can perform the analysis right at the source, avoiding the need for expensive, labor-intensive canister sampling. The vacuum pump interface allows the data system to turn the external vacuum pump ON/OFF under PeakSimple control. The vacuum pump is used to draw ambient air through the traps for a precise amount of time, thus enabling the system to sample unattended. The built-in air compressor eliminates the hassle of transporting bulky air cylinders by providing an endless supply of combustion air for the FID/DELCD combination detector.

The DELCD is completely selective for compounds containing chlorine and/or bromine. Other analytes do not respond at all, even at very high levels. The DELCD actually operates on the FID exhaust gases. All contaminants are pre-combusted by the FID to CO2 and H2O before reaching the DELCD.

The first few peaks in the 8021 standard, especially vinyl chloride, are of special interest to many analysts. This chromatogram shows the expanded detail of the first few peaks (the VOC gases) in the analysis shown above. Note the exceptionally good resolution and peak shape delivered by SRI's dual trap technology.

Available Models: 8610-0114 TO-14 Air Monitoring GC System $ 25,550.00

Services
GMI Certified Service means:
  • Healthy operation of your instrument
  • Helping to ensure the quality of your results
  • Lowering cost of ownership through multilple service agreement options
  • Prolonging instrument serviceable life
  • Safe Operation of your equipment
  • Minimizing downtime increases productivity and minimizes revenue loss
  • Instrument Evaluation Services
  • Contract Refurbishing
  • Relocation Services
  • Equipment Finder Service
  • Training Courses
  • Depot Repair
  • Instrument Decommisioning & Disposal Services
Service Agreements


Bronze
Prevention
Plus
Silver
Assurance
Plus
Gold
Safety
Plus
Platinum
Premium
Plus
PM
Preventative Maintenance Visit
('tune up', including cleaning, lubrication, and adjustments)
1PM
or
1 Service Visit
Service Visit 1PM
or
1 Service Visit
1 2
Travel
Parts and Labor    

1 YEAR
Discounted Parts
Discounted Labor (As needed)
Parts

Lab Equipment Replacement Parts & Accessories

Click button to view parts which are available for this instruments and instruments like it in our brand new online parts shop.

We also carry instruments parts for the following other instruments categories.

WHY BUY FROM GMI?

Your trusted source for new, factory clearance & certified pre-owned lab instruments since 1995.

  • We routinely save discerning laboratories 30-80% with our recertified pre-owned and factory clearance instrument offerings.

  • Quality? ISO 9001:2008 certified means we remove 100% of the risk in buying ‘used’ laboratory equipment.

  • Warranties from 90 days to a year as well as multi-year service agreements are available.

GMI is an ISO 9001:2008 certified company - proof that your instruments pass through a rigorous re-certification process to ensure that it arrives at your laboratory defect-free and in full working order.
We are neither an auction company nor an instrumentation broker. GMI employs our own factory-trained engineers to ensure full control of this process.
Unlike small-time businesses and brokers, GMI goes beyond offering money-back promises. We offer real product warranties.
Apart from our meticulous inspection processes, GMI’s available warranties and multi-year service agreements guarantee customer satisfaction - no need to go through frustrating and time-consuming product returns!
Additionally, all items are thoroughly cleaned and professionally packaged/crated with care to insure they arrive in your lab ready for use.